ER36G, ER36GI Revised 04/13/12 Page 1/3 Document # PG05-002 ® Renaissance 36” Wide All Gas Ranges warning • • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. PLANNING GUIDE Electrical Circuit Required Total Connected Load 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, 3 prong electrical outlet 5.0 Amps. @120 Vac, 60 Hz, Electrical Requirements All tolerances ±1/16” (±1.6 mm) unless otherwise noted. 46 7/8” (119.1 cm) 29” (73.6 cm) 27 13/16” (70.6 cm) 26 3/4” (67.9 cm) 24 5/8” (62.5 cm) Front of open door Front of handle Front edge of bull nose Front panel Rear of front panel7 9” (22.9 cm) 1 1/4” (3.2 cm) Grates extend 1 1” above trim 2” (5.1 cm) 19” (48.2 cm) 1 9/16” (4.0 cm) ER36GI: Partial stainless steel side panel 3” (7.6 cm) ER36G: Full stainless steel side panels D 15 1/4” (38.7 cm) B 35 3/4” (90.8 cm) to 37 7/8” (96.2 cm) A (A) 1 3/4” (4.4 cm): Model AER36GLBG (low profile) 2 (B) 6” (15.2 cm): Model AER36GBG6 3, 5 (C) 9” (22.9 cm): Model AER36GBG9 4, 5 (D) 24” (61.0 cm): Model AER36GBG24 4, 5 Product width: 35 7/8” (91.1 cm) ER36G/ER36GI Dimensions Side View ER36G/ER36GI Available backguards NOTE: Neither model is compatible with raised vents. NOTES: 1. 2. 3. 4. 5. 6. 7. Trim thickness is 1/4” (6 mm) with optional self-rimming kit installed (ER36GI only). Standard on model ER36GI. Optional on model ER36G. Standard on model ER36G. Optional on model ER36GI. Optional on both models. Not for use with self rimming installations. ER36G is not equipped for self-rimming installation. ER36G is designed for freestanding installations. ER36GI is designed for installation in a recessed cabinet or island. This dimension is shortened to 24" (61.0 cm) when the selfrimming kit is installed (ER36GI only). All specifications subject to change without notice. C www.dacor.com Phone: (800) 793-0093 ER36G, ER36GI Revised 04/13/12 Page 2/3 Document # PG05-002 Renaissance 36” Wide All Gas Ranges PLANNING GUIDE All tolerances +1/16” (+1.6 mm) -0 unless otherwise noted. A* B C 36 1/16” (91.6 cm) 30” (76.2 cm) minimum 36” (91.4 cm) recommended 37 7/8” (96.2 cm) maximum B * See the Cutout dimensions below for self-rimming installations 13” (33.0 cm) max.4 NOTES: Non-combustible surface along back wall recommended 30” (76.2 cm) min.1 18” (45.7 cm) min.1, 4 1. Top of finished counter 10” (25.4 cm) min. to combustible side walls above the range (both sides) A 2. Utilities may be located in the lower left corner of the adjacent right cabinet (recommended). Consult local code. Self-rimming kit is included with model ER36GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back. ER36G is not equipped for self-rimming installation. Suggested location of utilities3 Note 2 1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements. 4 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the range. C Cabinet Cutout Dimensions 10” min. (25.4 cm) to any combustibles above counter both sides 10” min. (25.4 cm) Rear wall or to any combustibles countertop edge above counter both sides Non-comubustible rear wall recommended 35 1/4” (89.5 cm) countertop opening 36” (91.4 cm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop height: 35 1/2” (90.2 cm) min. 37 5/8” (95.6 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. 35 1/4” (89.5 cm) countertop opening 24” (61.0 cm) 36” (91.4 cm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop overhang 2 1/8” (5.4 cm) max. Countertop height: 35 1/2” (90.2 cm) min. 37 5/8” (95.6 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. 24 1/8” (61.3 cm) Countertop overhang 2 1/8” (5.4 cm) max. Self-Rimming Cutout Dimensions Cabinet Depth Greater Than 24 Inches (ER36GI only) Self-Rimming Cutout Dimensions Cabinet Depth Exactly 24 Inches (ER36GI only) All specifications subject to change without notice. 3/4” min. (1.9 cm) Countertop overhang www.dacor.com Phone: (800) 793-0093 ER36G, ER36GI Revised 04/13/12 Page 3/3 Document # PG05-002 Renaissance 36” Wide All Gas Ranges CL 15” (38.1 cm) 12 1/2” (31.8 cm) PLANNING GUIDE 12” (30.5 cm) 15 7/8” (40.3 cm) to 18” (45.7 cm) 2 1/2” (6.4 cm) 1” (2.5 cm) 3 1/2” CL (8.9 cm) 3 3/4” (9.5 cm) Back of Range Utility Clearance Behind Range GAS SUPPLY PRESSURE REQUIREMENTS Gas Type Manifold Pressure* (WC) Min. Gas Supply Pressure (WC) Max. Input Pressure Natural 5” 6” 1/2 psi LP 10” 11” 1/2 psi IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it). The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093